Short answer
The maximum permitted height of a building depends on the area's building coefficient, from 10.75 m for a coefficient up to 0.4 to at most 32 m for a coefficient of 2.6 and above, under Article 210 par. 1 of the Spatial and Urban Planning Code (Law 5306/2026), ΦΕΚ (Government Gazette) Α΄ 88/08.06.2026. It is measured from the final ground level or, where the facades stand on the street line, from the pavement level (par. 3).
What applies today
- Provision
- Article 210 of the Spatial and Urban Planning Code (Law 5306/2026)
- Last amended by
- Not amended
- Last checked
The maximum permitted height of a building depends on the area’s building coefficient (συντελεστής δόμησης, Σ.Δ.), under Article 210 par. 1 of the Spatial and Urban Planning Code (Law 5306/2026, ΦΕΚ (Government Gazette) Α΄ 88/08.06.2026). This page sets out the height table, where height is measured from, the notional envelope, and what is allowed above the maximum height. It is a translation of the Greek guide; the Greek text of the ΦΕΚ is the one that applies.
Which provision applies on 11.11.2026
Article 210 of the Code applies, no longer Article 15 of Law 4067/2012. Annex Β΄ of the Code maps Article 15 of Law 4067/2012 to Article 210, and the codified provisions were repealed by Article 477 of the Code.
We found no amendment of Article 210 in any ΦΕΚ Α΄ issue from 89/2026 to 185/09.11.2026, the latest series Α΄ issue we found published on 11.11.2026.
Height per building coefficient: Article 210 par. 1
The maximum height depends on the permitted building coefficient of the area. Article 210 par. 1 sets seven bands:
| Coefficient of the area | Maximum permitted height | Case of par. 1 |
|---|---|---|
| up to 0.4 | 10.75 m | case α΄ |
| up to 0.8 | 14 m | case β΄ |
| up to 1.2 | 17.25 m | case γ΄ |
| up to 1.6 | 19.50 m | case δ΄ |
| up to 2 | 22.75 m | case ε΄ |
| up to 2.6 | 26 m | case στ΄ |
| 2.6 and above | Ten times the permitted coefficient, with a maximum height of 32 m | case ζ΄ |
The table is the general rule. Under Article 196 par. 5 case α΄ of the Code, special planning provisions prevail over the general provisions of the Section, subject to case β΄. Before you apply the table, check whether the area’s building terms set another height.
Where height is measured from: Article 210 par. 3
Height is measured from the final ground level or from the pavement. Under Article 210 par. 3, the maximum height at every point of the facades is measured from the final ground level at the measuring point, or from the pavement level if the facades stand on the street line (ρυμοτομική γραμμή).
Three definitions of Article 197 of the Code complete the rule:
- Building height (case 89): the vertical distance from the point where the facade meets the finally formed ground to the level of the final top surface of the last storey, without insulation and finishes. In a building with a pitched roof, to the level of the underside of the lowest roof bearing.
- Maximum permitted building height (case 46): the height of the top level of the building, above which all construction is forbidden except the installations that are allowed specifically and restrictively.
- Final ground level (case 54): the ground level as finally formed by excavation, fill or paving.
Par. 3 has two more rules. On plots facing more than one public space with different maximum heights, when at least one of them is not set under this paragraph, the lower height is kept up to 9 m from the building line it corresponds to, unless the area’s special building terms say otherwise. For a basement with a sunken courtyard (cour anglaise), measuring starts from the final ground level of the ground floor at that position.
Excavation and fill: Article 210 par. 4
The final ground level may not be more than 1.50 m above or below the natural one. Under Article 210 par. 4, excavation or fill in the plot’s open spaces is allowed on that condition. On plots with a slope above 20%, the natural ground may be lowered by up to 2 m and filled by up to 1.50 m. Beyond those limits an opinion of the Architecture Council (Σ.Α.) is required.
The notional envelope: Article 210 par. 5
The building must fit inside the notional envelope (ιδεατό στερεό), which limits the height of the street facade according to the width of the street. Article 197 case 30 of the Code defines it as the above-ground solid within which the building and its installations may be built. Article 210 par. 5 sets it with three surfaces:
- On the plot’s frontages, a vertical surface through the building line, whose top points are at a height of 1.5 Π, not less than 7.50 m, above the corresponding points of the pavement kerb (case α΄).
- An inclined surface through the top of the vertical one, forming with it an acute angle with a tangent of 1:1.50 (case β΄).
- On the other sides, vertical surfaces through the plot boundaries or through the limits of the required distances (case γ΄).
Π is defined in Article 198 of the Code: the length of the perpendicular to the building line up to its intersection with the opposite approved building line of the same street, or its extension. Under par. 5, balconies with their railings and safety parapets, architectural projections and decorative elements, movable shading systems and movable canopies may fall outside the envelope.
Height increase: Article 210 par. 8
The maximum height may be increased by up to 1 m or 2 m, under conditions. Article 210 par. 8 allows up to 1 m when one of four conditions is met, and up to 2 m when two are met, after an opinion of the Architecture Council:
- At least 50% of the ground floor is used for parking (case α΄).
- The building stands on pilotis and its free semi-outdoor space is used only for parking (case β΄).
- A planted flat roof or planted pitched roof covers more than 50% of the net roof area (case γ΄).
- The permitted site coverage of the plot is reduced by 5% (case δ΄).
Cases γ΄ and δ΄ carry one more condition. Under Article 196 par. 6 of the Code, the incentives and increases of Article 204, of cases γ΄ and δ΄ of par. 8 of Article 210 and of pars. 1 and 2 of Article 222 may apply only where they are incorporated in Local and Special Urban Plans through incentive zones. Par. 8 applies subject to the legislation on the protection of antiquities (Law 4858/2021) and, under its last sentence, also where the maximum height was set by decree, unless the decree expressly provides otherwise.
What is allowed above the maximum height
Above the maximum permitted height, only the structures listed in Article 214 of the Code are allowed. Under Article 214 par. 2, inside the notional envelope these include:
- Chimneys, ventilation ducts, solar and photovoltaic systems (case α΄).
- Stairwell heads with a lift stop at roof level, up to 4.20 m in external height, and without a lift stop, up to 3.40 m, above the finished surface of the last storey (case β΄).
- Safety parapets and railings (case γ΄), pergolas and structures supporting plants (case ε΄).
For pitched roofs, Article 197 case 90 sets that the roof height, unless otherwise specified, may not exceed 2 m above the maximum permitted height of the area.
Derogations and scope
Derogations on height are granted by ministerial decision, in two cases. Under Article 210 par. 2, by decision of the Minister of Environment and Energy after an opinion of the Central Architecture Council, derogations are allowed for special buildings other than offices in areas with a coefficient up to 1.2, with maximum values of 13 m, 18 m and 21 m per coefficient band (case α΄), and for a vertical extension of a building with a lawful building permit, where the building coefficient has not been used up (case β΄).
Article 210 is not among the provisions that Article 196 pars. 2 and 3 of the Code list as applying outside an approved town plan and in lawfully existing settlements without an approved town plan. Height there is set by the provisions in force for the area.
Sources
- Written by
- Dimosthenis Kanelakis, Co-Founder & COO
An information tool, not legal advice. Professional responsibility remains with the engineer.