Short answer
The areas listed in Article 206 par. 5 of the Spatial and Urban Planning Code (Law 5306/2026), ΦΕΚ (Government Gazette) Α΄ 88/08.06.2026, count towards the building coefficient, starting with roofed spaces closed on all sides; the areas listed in par. 6 do not. Article 206 codifies Article 11 of Law 4067/2012 (ΝΟΚ, the New Building Regulation), with different letters for some cases.
What applies today
- Provision
- Article 206 of the Spatial and Urban Planning Code (Law 5306/2026)
- Last amended by
- Not amended
- Last checked
The areas listed in Article 206 par. 5 of the Spatial and Urban Planning Code (Law 5306/2026, ΦΕΚ (Government Gazette) Α΄ 88/08.06.2026) count towards the building coefficient (συντελεστής δόμησης, Σ.Δ.); the areas listed in par. 6 do not. This page sets out both lists, the limits attached to them, and the point where the case letters differ from the ΝΟΚ. It is a translation of the Greek guide; the Greek text of the ΦΕΚ is the one that applies.
Which provision applies on 11.11.2026
Article 206 of the Code applies, no longer Article 11 of Law 4067/2012. Annex Β΄ of the Code maps Article 11 of Law 4067/2012 to Article 206, and Article 477 of the Code repealed the codified provisions listed in Annex Α΄ from the day the Code took effect.
We found no amendment of Article 206 in any ΦΕΚ Α΄ issue from 89/2026 to 185/09.11.2026, the latest series Α΄ issue we found published on 11.11.2026.
How the permitted floor area is calculated
The permitted floor area is the plot area multiplied by the building coefficient. Article 197 case 82 of the Code defines the coefficient as the number which, multiplied by the area of the plot, gives the total permitted built area. Article 206 par. 4 states the calculation: the plot area times the coefficient in force.
Three points before you calculate:
- The coefficient of an area is not in Article 206. It comes from the area’s building terms, and under Article 196 par. 5 case α΄ special planning provisions prevail over the general provisions of the Section, subject to case β΄.
- Under Article 206 par. 1, the coefficient is set as a number. Coefficients that follow indirectly from provisions older than 09.07.2012 remain in force until they are set numerically.
- For a plot facing more than one public space with different coefficients, par. 2 sets the coefficient as the sum of each frontage length times its coefficient, divided by the sum of the frontage lengths.
What counts: Article 206 par. 5
Article 206 par. 5 lists four cases of areas that count towards the building coefficient:
- The areas of the building’s roofed spaces that are closed on all sides (case α΄).
- The areas of unheated roofed spaces with at least one open side, when the opening is shorter than 35% of the total perimeter of the space (case β΄).
- The areas of basements of any use other than those listed in par. 6 (case γ΄).
- The areas of open balconies and open semi-outdoor spaces (ημιυπαίθριοι χώροι), when their total area is more than 40% of the area permitted to be built (case δ΄).
What does not count: Article 206 par. 6
Article 206 par. 6 lists the areas that do not count, in cases α΄ to λγ΄. The table shows a selection, with the limit each case sets. For any other case, read the text of par. 6.
| Space | Limit or condition | Case of par. 6 |
|---|---|---|
| Open balconies and open semi-outdoor spaces | In total up to 40% of the area permitted to be built; semi-outdoor spaces up to 20% | case α΄ |
| Shared stairwells, with lifts, landings and corridors | Up to 30 m² per level and per stairwell; 40 m² at the entrance level | case δ΄ |
| Stairwell inside a self-contained property | Up to 25 m² per level and per stairwell | case ε΄ |
| Basement floors for parking and mechanical installations | For the uses of sub-cases θα΄ to θη΄ | case θ΄ |
| Basement of residential buildings for auxiliary uses | One floor, equal in area to the building’s coverage; its ceiling up to 1.20 m above the final ground level | case ι΄ |
| Lofts (σοφίτες) | Total area up to 1/2 of the floor below, without forming a separate storey | case ιδ΄ |
| Free space under pilotis | Area at least 50% of the area the building occupies, and the other conditions of the case | case ιστ΄ |
| Thermal insulation and cladding | The insulation in full; cladding up to 20 cm beyond the insulation | case ιη΄ |
| Closed mezzanines (κλειστά πατάρια) | Maximum width 2.20 m | case κθ΄ |
For the residential basement, case ι΄ adds that the floor may have a main use, in whole or in part, if it is a functional annex of a self-contained dwelling or dwellings and 50% of the main-use area is counted towards the coefficient.
Mezzanines and lofts: check the letter of the case
Case ιδ΄ of Article 206 par. 6 now covers lofts, not mezzanines. The exemption for mezzanines was repealed before the codification: Article 71 of Law 5197/2025 (ΦΕΚ Α΄ 76/16.05.2025) repealed case ιδ΄ of par. 6 of Article 11 of the ΝΟΚ, on not counting internal balconies (πατάρια) towards the building coefficient, subject to Article 68 of the same law.
Three things follow from the text of the Code:
- Article 206 par. 6 has no case for the internal balcony (πατάρι) of Article 197 case 28. That its area now counts is a consequence of the repeal of the exemption; par. 5 does not name it.
- Closed mezzanines (Article 197 case 37) still do not count, with a maximum width of 2.20 m (case κθ΄).
- Article 224 par. 16 of the Code still refers to case ιδ΄ of par. 6 of Article 206 as the provision on mezzanines, for the environmental offset it sets for certain building permits. That letter does not match today’s text of Article 206. In every citation, check the case letter against the text of the Code.
Outside the plan and in settlements without a plan
Article 206 also applies outside an approved town plan, with exceptions. Under Article 196 par. 2 case στ΄ of the Code, outside the plan Article 206 applies except par. 2 and cases ιγ΄, ιε΄ and ιστ΄ of par. 6 (the text adds “for Article 214”). Under par. 3 case στ΄, in lawfully existing settlements without an approved town plan Article 206 applies except case ιστ΄ of par. 6.
What to check in every study
- Cite Article 206 of the Code, not Article 11 of Law 4067/2012.
- Take the coefficient from the area’s building terms and check whether a special provision sets something different (Article 196 par. 5).
- Check both limits of case α΄ of par. 6 together: 40% for balconies and semi-outdoor spaces in total, 20% for semi-outdoor spaces.
- Under Article 196 par. 4, every numerical value set in the Section is the maximum permitted.
- Do not carry case letters over from the ΝΟΚ. Read them in the text of the Code.
Sources
- Written by
- Dimosthenis Kanelakis, Co-Founder & COO
An information tool, not legal advice. Professional responsibility remains with the engineer.